Product Description
| Rated power 415V kw | Ie current setting range Amp | S/C Icu breaking capacity kA | Type |
| 0.03 | 0.10 0.16 | 50 | MS132-0.16 |
| 0.06 | 0.16 0.25 | 50 | MS132-0.25 |
| 0.09 | 0.25 0.40 | 50 | MS132-0.4 |
| 0.12 | 0.40 0.63 | 50 | MS132-0.63 |
| 0.25 | 0.63 1.00 | 50 | MS132-1.0 |
| 0.55 | 1.00 .. 1.60 | 50 | MS132-1.6 |
| 0.75 | 1.60 2.50 | 50 | MS132-2.5 |
| 1.5 | 2.50 4.00 | 50 | MS132-4.0 |
| 2.2 | 4.00 6.30 | 50 | MS132-6.3 |
| 4.0 | 6.30 10.0 | 50 | MS132-10 |
| 5.5 | 8.00 12.0 | 25 | MS132-12 |
| 7.5 | 10.0 16.0 | 16 | MS132-16 |
| 9.0 | 16.0 20.0 | 15 | MS132-20 |
| 12.5 | 20.0 25.0 | 15 | MS132-25 |
| 15.5 | 25.0 32.0 | 10 | MS132-32 |
Advanced Motor ProtectionEquipped with integrated phase failure, overload, and short circuit protection, the MS132 manual motor starter safeguards motors against common electrical faults. The adjustable current setting allows precise calibration for specific operational needs, while the tripping class 10 ensures rapid response to abnormal conditions, minimizing downtime and potential damage.
Flexible Installation and UsageThis compact starter features DIN rail mounting, making it compatible with standard panels and enclosures. Its screw terminal connection simplifies wiring, and the any-position operating capability offers installation flexibility. Optional auxiliary contacts further enhance monitoring and control options for advanced motor protection systems.
FAQ's of MS132 Manual motor starters with short circuit:
Q: How does the MS132 manual motor starter provide motor protection?
A: The MS132 starter delivers protection against phase failure, overload, and short circuit conditions, safeguarding motor operation through its integrated functions and rapid Class 10 tripping.
Q: What is the process for adjusting the current setting on this starter?
A: To adjust the current setting, simply use the dial provided on the device. The range covers 0.1-32 A, enabling customization for different motor ratings and operational requirements.
Q: When should auxiliary contacts be used with the MS132 starter?
A: Auxiliary contacts are recommended when additional control or monitoring of starter status is needed, particularly for advanced automation systems or integrated alarm signaling.
Q: Where can the MS132 manual motor starter be installed?
A: It can be installed in any operating position on a standard DIN rail within a panel or enclosure, thanks to its compact size and standard mounting design.
Q: What are the benefits of using a manual motor starter with Class 10 tripping?
A: Class 10 tripping ensures fast response to overloads, reducing the risk of motor damage and prolonging equipment life. The manual control also allows flexible management during maintenance or emergencies.
Q: Is the MS132 compatible with both AC and DC voltage?
A: Yes, the MS132 supports a maximum voltage of 690 V AC and is compatible with AC/DC supply systems, making it suitable for a wide range of motor control applications.