Product Description
The nVent HOFFMAN MCD Series is a robust range of modular double-door enclosures made from high-quality mild steel. Designed for demanding industrial applications, these enclosures offer enhanced flexibility, superior protection, and easy customization.
Ideal for housing electrical and automation equipment, the MCD series supports various configurations and ensures long-lasting durability in indoor and covered outdoor environments
Features:
- Material: Frame: 1.5 mm painted steel. Doors: 2 mm painted steel. Rear, roof and side panels: 1.5 mm painted steel. Mounting plate: 3 mm galvanized steel. Bottom plates: 1 mm galvanized steel.
- Frame: Seam welded reversed open profiles with 25 mm hole pattern, according to DIN 43660. Including integrated external hole pattern.
- Door: Mounted with four hinges. Including door frame with 25 mm hole pattern. Doors cannot be reversed. Separate doors to be ordered for left hand door locking.
- Rear panel: Fitted by M6 torx screws. Standard facilities for rear doors mounting. Split rear panels in 1600 mm wide enclosures.
- Side panels: Supplied as an accessory.
- Roof panel: Removable.
- Lock: Espagnolette 4-point locking system in the main door and 2-point locking system in the slave door. Standard double-bit lock with 3 mm insert. Standard inserts, cylinders, lift handles and T-handles are available as accessories.
- Bottom plates: Consists of three or four (D>600) pieces.
- Mounting plate: Double folded and slides into position. Adjustable in depth by steps of 25 mm, with the MPD02 accessory. Supplied, attached on the outside of the enclosure packaging.
- Earthing: All panels are earthed through their fittings and equipped with a separate earthing stud.
- Finish: RAL 7035 structured powder coating.
- Protection: Complies with IP55 | TYPE 12 | IK 10.
- Mounting requirements: Standard delivery ready for combined installation. For stand-alone installation add side panels
| Model Number |
Height (mm) |
Width (mm) |
Depth (mm) |
Mounting Plate Height (mm) |
Mounting Plate Width (mm) |
Max. Enclosure Useful Depth (mm) |
| MCD18104R5 |
1800 |
1000 |
400 |
1694 |
999 |
310 |
| MCD18105R5 |
1800 |
1000 |
500 |
1694 |
999 |
410 |
| MCD18124R5 |
1800 |
1200 |
400 |
1694 |
1199 |
310 |
| MCD18125R5 |
1800 |
1200 |
500 |
1694 |
1199 |
410 |
| MCD18126R5 |
1800 |
1200 |
600 |
1694 |
1199 |
510 |
| MCD20105R5 |
2000 |
1000 |
500 |
1894 |
999 |
410 |
| MCD20106R5 |
2000 |
1000 |
600 |
1894 |
999 |
510 |
| MCD20108R5 |
2000 |
1000 |
800 |
1894 |
999 |
710 |
| MCD20124R5 |
2000 |
1200 |
400 |
1894 |
1199 |
310 |
| MCD20125R5 |
2000 |
1200 |
500 |
1894 |
1199 |
410 |
| MCD20126R5 |
2000 |
1200 |
600 |
1894 |
1199 |
510 |
| MCD20128R5-04 |
2000 |
1200 |
800 |
1894 |
1199 |
710 |
| MCD22126R5 |
2200 |
1200 |
600 |
2094 |
1199 |
510 |
Reliable Protection for Electrical InstallationsThis enclosure provides outstanding protection for electrical and industrial panels, ensuring safety and stability in harsh environments. The powder-coated mild steel and polyurethane foam gasket offer resilience against dust, moisture, and mechanical impacts. Its double hinged doors and three-point locking system provide secure access while the IP55 rating guarantees dust and water resistance, making it ideal for factories, distribution centers, and heavy-duty applications.
Flexible Design and Easy IntegrationEngineered for adaptability, the enclosure offers removable gland plates for convenient cable management and mounts internal accessories like shelf brackets and plates. Standard external dimensions meet typical requirements, while custom sizing is available for specialized needs. The louvre/vent grills enhance airflow, maintaining optimal operating conditions. Suitable for a wide network of dealers, distributors, and exporters in India, installation is straightforward and the product integrates seamlessly into existing panel setups.
FAQ's of Mild steel combinable version, Double Door Enclosure - Floor Standing:
Q: How can the Mild Steel Double Door Enclosure be installed in an industrial environment?
A: The enclosure is designed for floor standing with robust mounting provisions. Installation involves securing the base to the floor, using the provided mounting plate and shelf brackets for internal components, and connecting earth bolts for grounding. Removable gland plates simplify cable entry during setup.
Q: What benefits does the 3-point locking system provide for secure operations?
A: The 3-point locking mechanism distributes locking force across the entire door, preventing unauthorized access and enhancing protection against tampering or forced entry. It ensures that both doors remain firmly closed, safeguarding sensitive electrical equipment inside.
Q: Where is the enclosure typically used and who can supply it in India?
A: This enclosure is widely used in industrial and electrical panel installations, control rooms, and manufacturing facilities. It is available through a network of dealers, distributors, exporters, retailers, suppliers, traders, and wholesalers across India.
Q: What is the process for cable management within this enclosure?
A: Cable management is made easy with removable gland plates situated at the base or side. Installers can remove these plates, route cables efficiently, and reseal the enclosure to maintain its IP55-rated dust and water resistance.
Q: Why is polyurethane foam gasket chosen for this enclosure?
A: Polyurethane foam gasket offers excellent sealing properties, maintaining the enclosure's IP55 protection level by preventing water ingress and dust accumulation, which is essential for safeguarding sensitive electrical panels.
Q: When is it advisable to use customizable dimensions for this type of enclosure?
A: Custom dimensions are recommended when standard sizes do not accommodate particular installations, such as oversized electrical equipment or unique site requirements. The supplier can tailor the enclosure's dimensions to meet specific application needs.
Q: How does the louvre/vent grill provision improve usage and performance?
A: Louvre or vent grills promote efficient airflow and ventilation, preventing heat buildup inside the enclosure. This ensures electronics and electrical components operate within safe temperature ranges, enhancing reliability and extending equipment life.